Red Wireless Interconnected Photoelectric Smoke Alarm with 10 year battery x 5 pack

Code: R10RF-X5
  • Wireless interconnected photoelectric
  • 10 year sealed lithium battery
  • Simple DIY setup (no sparky required)
  • 10 year warranty
  • 60 day money back guarantee
  • Free shipping Australia wide!
25% off stocktake sale – hurry limited stock!

$399.75

In Stock

or 4 fortnightly payments of $99.94 with Afterpay More info

Australian Standard LogoAS3876:2014
Payment MethodsPayment Methods
Secure CheckoutSecure Checkout

Description

The Red brand of smoke alarms are a high quality smoke alarm which can be paired with other Red brand smoke alarms (including the hardwired model).

  • Fully compliant to Australian Standard AS 3786:2014
  • 10 year warranty
  • 60 day money back guarantee
  • Interconnectable with 20 other Red brand smoke alarms (including Red hardwired alarms)
  • Free shipping Australia wide
  • Trusted QLD family business
  • Model No: R10RF

 

Download R10RF instruction manual (including pairing instructions)
Download R10RF Datasheet

Law in Queensland says that wireless interconnected photoelectric smoke alarms must be installed on each level:

  1. In every bedroom; and,
  2. In hallways which connect bedrooms and the rest of the dwelling; or
  3. If there is no hallway, between the bedrooms and other parts of the storey; and
  4. If there are no bedrooms on a storey at least one smoke alarm must be installed in the most likely path of travel to exit the dwelling.

The legislation also states;

Where practicable smoke alarms must be placed on the ceiling. Smoke alarms must not be placed:

  1. Within 300mm of a corner of a ceiling and a wall,
  2. Within 300mm of a light fitting,
  3. Within 400mm of an air-conditioning vent,
  4. Within 400mm of the blades of a ceiling fan.

There are special requirements for sloping ceilings, stairways, and ceilings with exposed beams. Specific requirements are further explained in the Building Fire Safety Regulation 2008.

If it is not practical for the prescribed location requirements to be met (e.g. may be affected by fumes from cooking or hot steam from a bathroom), the owner may put the alarm at another location that will still provide a warning to occupants of the building.

The floorplan below is produced by the Queensland Fire and Emergency Services (QFES) and shows recommended smoke alarm locations within a building.

 

Wireless Interconnected Photoelectric Smoke Alarm Placement Recommendations

Additional information

Compliance

AS 3786:2014

Power

10 year sealed lithium battery (non-replaceable)

Operating Current

< 100mA at 3V

Standby Power

< 0.04 mW

Humidity Range

5% to 95% relative humidity (RH)

Ambient Air Temperature for Operation

0°C to 45°C

Wireless Frequency (RF)

433.92MHz

Alarm Sound

85 dB at 3m minimum

Number of Devices

Up to 20 units

Operating Distance

30m indoor use line of sight
100m in free field

Dimensions

140mm x 140mm x 39mm

Lifespan

10 years

Warranty

10 years

Model

R10RF